AFIAL is designed to seamlessly integrate with your existing systems, providing a powerful and intuitive solution for any mission. AFIAL utilize laser pointers for precise targeting and NVG illumination for enhanced situational awareness.
Wavelength (Red)
- Laser 1. Visible Target Marker: 635-650 nm
- IR Laser 2. Invisible Target Marker: 830-850 nm
- IR LED. Invisible Illuminator: 830-850 nm
Low Power Laser
- Laser 1. Visible Target Marker: < 1 mW; LC 2
- IR Laser 2. Invisible Target Marker: < 0.7 mW; LC 1
- IR LED. Invisible Illuminator: 2 x 40 mW
High Power Laser
- Laser 1. Visible Target Marker: ~30 mW; LC 3B
- IR Laser 2. Invisible Target Marker: ~30 mW; LC 3B
- IR LED. Invisible Illuminator: 2 x 40 mW
Standard Laser
- EN/IEC 60825-1:2014
Differences (Typical)
- Laser 1. Visible Target Marker: < 0.5 mrad
- IR Laser 2. Invisible Target Marker: < 0.5 mrad
- IR LED. Invisible Illuminator: -
Setting Range
- +/- 20 mrad
Battery Type
- CR123, CR123A, IEC CR17345, ANSI 5018LC, lithium 3-volt
Battery Life Capability at High Power Laser
- Minimum 5 hours
Operating Temperature
- C1-A1 as per MIL-STD 810G -32°C to +49°C
Storage Temperature
- C1-A1 as per MIL-STD 810G -46°C to +71°C
Water Resistance
- Submersion up to 8 meters (2 hours)
Relative Humidity
- Up to 100%
NOHD/eNOHD
- Laser 1. Visible Target Marker: 320m/2.25km
- IR Laser 2. Invisible Target Marker: 180m/1.3km
- IR LED. Invisible Illuminator: -
Weight (Including Battery)
- Approximately 170 g (+/-5 g)
Dimensions (LxWxH)
- 79.5 mm x 59 mm x 24 mm (+/-1 mm)
Compliance with Standards
- RoHS/REACH